6
Battery Installation / Charging
Alkaline Battery Installation: Remove the BULLSEYE from its carrying
case. Hold the unit so the accessory connector is pointing upwards.
Remove the dust cap from the accessory connector. Loosen the two
thumb screws and remove the battery access cover. Install four “C” cell
alkaline batteries as shown on the label diagram inside the battery
compartment noting the (+) and (-) terminals.
Replace the battery access cover. Firmly tighten the two thumbscrews.
Replace the accessory connector dust cap.
Nickel Metal Hydride Batteries: Rechargeable batteries require an initial
and subsequent charging time of approximately 3 hours. It may require
2 or 3 charging cycles to obtain maximum battery life. To charge, remove
the dust cap from the accessory connector. Insert the cannon adapter into
the accessory connector and tighten. Insert the charger into the cannon
adapter. Plug the charger into a 110-volt outlet. (European and Australian
chargers allow plugging into appropriate outlets.)
Battery installation diagram /
Serial number label
Cannon Adapter
Charger
The batteries may also be charged with a 12-volt auto cigarette lighter
adapter. The charge status indicator located on the back of the housing
will remain solid when the unit is charging. The indicator will blink when
fully charged. When charged, unplug the charger from the outlet and
remove the cannon adapter from the accessory connector.
7
Battery Installation / Charging
Built-in overcharging protection prevents damage if the unit is left on
charge after being fully charged. There is also charge protection for
attempting to charge alkaline batteries.
CAUTION: Do not attempt to charge alkaline or other
disposable batteries.
NOTE: Do not charge Ni-MH batteries when ambient
temperature exceeds 113 F° (45°C).
The rechargeable battery electronics include a charge error indicator. A
solid light on the right LED indicates an error with either the internal battery
connection, the charging temperature, or possible dead battery cell.
Contact your dealer service department if this light is displayed.
Rechargeable Battery Replacement - Remove the battery access cover.
A battery contact is located in the battery housing as illustrated. For proper
operation, a negative end of one rechargeable battery
must have the protective cover removed or "skinned"
and positioned to touch the contact in the housing
as illustrated. Follow the label diagram for the
other batteries. Replace with factory approved
NiMH batteries only. Once installed, replace the
battery access cover, firmly tighten the two screws
and replace the dust cap. Charge as instructed on
page 6. Refer to your local requirements for the
proper disposal of rechargeable batteries.
Battery Contact
Rechargeable Battery
Cover Removed
Charge Status Indicator
Solid - Charging
Blinking - Charging Complete
Charge Error
Indicator